Part Number Hot Search : 
090814 A3515 2C3506 FN2898 KD1083V LT2079AI FDQ7238S ENA0654
Product Description
Full Text Search
 

To Download TFS75 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TFS75v1.doc
__________________________________________________________________________________ VI TELEFILTER Filter specification TFS 75 1/3 __________________________________________________________________________________
1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 75 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae.
Version 3.2
06.01.02
Package, pin connection and 50 matching network 25 C 0 dBm (typ.) Max 10 dBm. for input: 190 49 pF. for output: 2,1 24 pF.
(see page 2.)
Data typ. value tolerance / limit ___________________________________________________________________________________________________ 24,8 dB max 26 dB Insertion loss (Reference level) ae ___________________________________________________________________________________________________ Reference frequency fc at operation temperature TO=70C (fCOT) *) 75.30 MHz 75.30 0,20 MHz ___________________________________________________________________________________________________ Relative frequency distance of fCAT within one set of 3 filters 9400 kHz max 20 kHz 1nd filter with fCAT = 65,9 MHz 200 kHz *) 3rd filter with fCAT = 87,1 MHz 200 kHz 11800 kHz max 20 kHz ___________________________________________________________________________________________________ 1 3 10 20 40 45 dB - band width dB - band width dB - band width dB - band width dB - band width dB - band width fc ... fc 2,8 MHz 6,00 6,06 6,27 6,41 6,55 6,60 0,9 MHz MHz MHz MHz MHz MHz dB max 1,0 max 1,0 max 3 min 40 min 45 min 50 dB dB dB dB dB dB
____________________________________________________________________________________________________________________________________________________________________________________________________________
Amplitude ripple (p-p):
____________________________________________________________________________________________________________________________________________________________________________________________________________
Relative attenuation arel fc fc 2.8 MHz fc 2.8 MHz fc 3.0 MHz fc 3,3 MHz 45 dB In the frequency range fc 3,3 MHz ... fc 20 MHz the limit line is of type SLOPING LINE. fc 20 MHz 60 dB In the frequency range fc 20 MHz ... fc 25 MHz the limit line is of type SLOPING LINE. fc 25 MHz 55 dB fc 25 MHz fc 50 MHz 75 dB Group delay at operation temperature 25C Group delay at operation temperature 70C Group delay ripple (p-p): fc ... fc 3,0 MHz 4.96 4.98 175 s s ns
____________________________________________________________________________________________________________________________________________________________________________________________________________
max 5,0 s max 200 ns
____________________________________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________________________________
Deviation from linear phase (p-p): fc ... fc 2,8 (3,0) MHz Triple transit attenuation compared to main signal
6,5 (16) 48 1,6/1,7 60 dB dB dB
____________________________________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________________________________
Input/Output return loss with matching network (S11/S22): Crosstalk Substrate material Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature
____________________________________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________________________________
LiNbO3 -76,466 ppm/K -94 ppm/K
____________________________________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________________________________
fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
Operating temperature range + 70 1 C Storage temperature range - 40 C ... + 85 C ___________________________________________________________________________________________________ *) For the 2nd filter fCOT is its reference frequency fC at the operation temperature OT = 70 C 1 C. The reference frequency at ambient temperature fCAT for this 2nd filter and the from it resulting relative frequency distance have to be determined. Responsible: Generated: Weinberg Checked/Approved: Dr. Bert Wall
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS75v1.doc
__________________________________________________________________________________ VI TELEFILTER Filter specification TFS 75 2/3 __________________________________________________________________________________
3. Package 38,10 mm
Version 3.2
06.01.02
TFS 75 tft L1
25,4 mm top view
Pin 4 Pin 6 Pin 17 Pin 15 Pin 12,14,26,28
Input Input RF Return Output Output RF Return Pakage Ground
5.0 Max 5.00.5
5,08 3,81
4
6
12 14 20,32
28 26 22,86 33,02 4. 50 matching network:
17 15
L1 C1 C2
4
6
12 14
C3
C1 = 8 pF. C2 = 18 pF. L1 = 150 nH. C3= 27 pF.
28 26 17 15
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS75v1.doc
__________________________________________________________________________________ VI TELEFILTER Filter specification TFS 75 3/3 __________________________________________________________________________________ Air reflow temperature conditions
Version 3.2
06.01.02
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information


▲Up To Search▲   

 
Price & Availability of TFS75

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X